The items listed below, can be used in combination with the UIP500 , UIP1000 and UIP2000 ultrasonic processors. | Item | Description | Picture | | UIP500-115 | industrial ultrasonic processor UIP500 (500W), frequency 20kHz (auto-scan), amplitude 25 micron (adjust. 50-100%), continuous or dry operation possible, 3m cable transducer to generator, interface for remote control or UPC-control, 115V~1P (6.3A), 50-60Hz Transducer (LxWxH): approx. 112x71x330mm | | | UIP1000-115 | industrial ultrasonic processor UIP1000 (1000W), frequency 20kHz (auto-scan), amplitude 25 micron (adjust. 50-100%), continuous or dry operation possible, 3m cable transducer to generator, interface for remote control or UPC-control, 115V~1P (13A), 50-60Hz Transducer (LxWxH): approx. 112x71x440mm | | | UIP500-230 | industrial ultrasonic processor UIP500 (500W), frequency 20kHz (auto-scan), amplitude 25 micron (adjust. 50-100%), continuous or dry operation possible, 3m cable transducer to generator, interface for remote control or UPC-control, 230V~1P (3.2A), 50-60Hz Transducer (LxWxH): approx. 112x71x330mm | | | UIP1000-230 | industrial ultrasonic processor UIP1000 (1000W), frequency 20kHz (auto-scan), amplitude 25 micron (adjust. 50-100%), continuous or dry operation possible, 3m cable transducer to generator, interface for remote control or UPC-control, 230V~1P (6.3A), 50-60Hz Transducer (LxWxH): approx. 112x71x440mm | | | UIP2000-230 | industrial ultrasonic processor UIP2000 (2000W), frequency 20kHz (auto-scan), amplitude 17 micron (adjust. 50-100%), continuous or dry operation possible, 3m cable transducer to generator, interface for remote control or UPC-control, 230V~1P (13A), 50-60Hz | | | BS2d18F | sonotrode BS2d18F, for UIP500 to UIP2000, with decoupling stainless steel flange, for flow cell or batch operation, titanium, tip diam.18mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:3.5 | | | BS2d22F | sonotrode BS2d22F, for UIP500 to UIP2000, with oscillation-decoupling stainless steel flange, for flow cell or batch operation, titanium, tip diam. 22mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:2.4 | | | BS2d34F | sonotrode BS2d34F, for UIP500 to UIP2000, with oscillation-decoupling stainless steel flange, for flow cell or batch operation, titanium, tip diam. 34mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:1.0 | | | BS2d40F | sonotrode BS2d40F, for UIP500 to UIP2000, with oscillation-decoupling stainless steel flange, for flow cell or batch operation, titanium, tip diam. 40mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:0.7 | | | BS2d50F | sonotrode BS2d50F, for UIP500 to UIP2000, with oscillation-decoupling stainless steel flange, for flow cell or batch operation, titanium, tip diam. 50mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:0.5 | | | BS2d18 | sonotrode BS2d18, for UIP500 to UIP2000, for use with flange RFLA100, for flow cell or batch operation, titanium, tip diam. 18mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:3.5 | | | BS2d22 | sonotrode BS2d22, for UIP500 to UIP2000, for use with flange RFLA100, for flow cell or batch operation, titanium, tip diam. 22mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:2.4 | | | BS2d34 | sonotrode BS2d34, for UIP500 to UIP2000, for use with flange RFLA100, for flow cell or batch operation, titanium, tip diam. 34mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:1.0 | | | BS2d40 | sonotrode BS2d40, for UIP500 to UIP2000, for use with flange RFLA100, for flow cell or batch operation, titanium, tip diam. 40mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:0.7 | | | BS2d50 | sonotrode BS2d50, for UIP500 to UIP2000, for batch operation, titanium, tip diam. 50mm, male thread M14x1, approx. length 125mm (w/o thread), amplitude ratio approx. 1:0.5 | | | B2-1.2 | booster B2-1.2, for UIP500 to UIP2000, for mechanical increase (or decrease) of the amplitude at the sonotrode, amplitude ratio 1:1.2 (or 1:0.83), titanium, female threads M14x1, for use with titanium thread bolts (TiM14x1) | | | B2-1.4 | booster B2-1.4, for UIP500 to UIP2000, for mechanical increase (or decrease) of the amplitude at the sonotrode, amplitude ratio 1:1.4 (or 1:0.71), titanium, female threads M14x1, for use with titanium thread bolts (TiM14x1) | | | B2-1.8 | booster B2-1.8, for UIP500 to UIP2000, for mechanical increase (or decrease) of the amplitude at the sonotrode, amplitude ratio 1:1.8 (or 1:0.56), titanium, female threads M14x1, for use with titanium thread bolts (TiM14x1) | | | B2-2.2 | booster B2-2.2, for UIP500 to UIP2000, for mechanical increase (or decrease) of the amplitude at the sonotrode, amplitude ratio 1:2.2 (or 1:0.45), titanium, female threads M14x1, for use with titanium thread bolts (TiM14x1) | | | B2-2.6 | booster B2-2.6, for UIP500 to UIP2000, for mechanical increase (or decrease) of the amplitude at the sonotrode, amplitude ratio 1:2.6 (or 1:0.38), titanium, female threads M14x1, for use with titanium thread bolts (TiM14x1) | | | FLA100 | oscillation-decoupling flange FLA100, permanently attached to the sonotrode, diam. 100mm, stainless steel, with O-Ring (NBR) for mounting to flow cells FC100L1-1S or FC100L1K-1S | | | RFLA100 | O-ring flange RFLA100, with O-ring sealing (2xNBR) to the sonotrode, diam. 100mm, stainless steel, for use with sonotrodes BS2d18, BS2d22, BS2d34 or BS2d40, with O-Ring (NBR) for mounting to flow cells FC100L1-1S or FC100L1K-1S | | | FC100L1-1S | flow cell FC100L1-1S, decomposable stainless steel reactor, max. pressure 10 bars, for UIP500 to UIP2000 in combination with sonotrode flange and stand ST2, NBR O-rings, tube connectors (1/2") with clip | | | FC100L1K-1S | flow cell FC100L1K-1S, decomposable stainless steel reactor with cooling jacket, max. pressure 10 bars, for UIP500 to UIP2000 in combination with sonotrode flange and stand ST2, NBR O-rings, tube connectors (fluid 1/2", cooling 1/4") with clip | | | XTFC100L1-1S | extension XTFC100L1-1S, for flow cells FC100L1-1S or FC100L1K-1S, max. pressure 10 bars, stainless steel, for use with longer sonotrodes with sonotrode flange of up to 250mm total length, tube connector (fluid 1/2") with clip | | | FCB100 | flow cell bottom FCB100, for flow cells FC100L1-1S or FC100L1K-1S, replacement in case of cavitation wear, stainless steel | | | Insert22 | Insert22, for flow cells FC100L1-1S or FC100L1K-1S, for reduction of the reactor volume, for use with sonotrode BS2d18(F) or BS2d22(F), NBR O-rings, stainless steel | | | Insert34 | Insert34, for flow cells FC100L1-1S or FC100L1K-1S, for reduction of the reactor volume, for use with sonotrode BS2d18(F), BS2d22(F) or BS2d34(F), NBR O-rings, stainless steel | | | ST2 | stand ST2, stainless steel, for UIP500 to UIP2000, required for flow cells FC100L1-1S or FC100L1K-1S, adjustable in height, collecting tray | | | SPB2 | sound protection box SPB2 for UIP500 to UIP2000, e.g. for use with stand ST2 and flow cells FC100L1-1S oder FC100L1K-1S | | | PowMet230 | power meter PowMet230, versatile, for display of current power, cumulated energy and cumulated operation time, 230V~1P, 50-60Hz | | | PowMet115 | power meter PowMet115, versatile, for display of current power, cumulated energy and cumulated operation time, 115V~1P, 50-60Hz | |
|